Product for Substations:

Trip circuit supervision relay - TCS

Trip Circuit Supervision Relay For DIN35 rail TCS421D Trip Circuit Supervision Relay For Panel Mount TCS461P

Trip circuit supervision relay TCS provides customer mounting flexibility (3 different mounting styles - DIN35, panel mount, Combiflex), reduces cost and space requirements (it can supervise from one up to three coils circuits in single relay) and provides two principles of operation (supplied with active supply or it is passively supplied). Input voltages are standard substation voltages; 24 VDC, 48VDC, 110VDC, 125VDC, 220VDC.
For proper electrical networks operation, proper protection and circuit breaker operation in meduim and high voltage substations is crucial. For proper circuit breaker operation, healty trip coil circuit is crucial. The healtiness of circuit breaker trip coil circuit is monitored by the trip circuit supervision relay TCS which monitors the circuit in open and close circuit breaker position (ANSI 74TC). In normal operation TCS supervision relay is always energised. In case of trip coil circuit fault, trip voltage fault or TCS relay fault, supervision relay will deenergise and indicate "Trip Circuit Fault".More...

Trip Circuit Supervision Relay For Combiflex SPER 1C1 and RXEM 1 Replacement TCS411C

 

BCD decoder - BCD 100 / x

BCD 100/26 - 26 input tap changer position to BCD code decoder Tap changer BCD 100 decoder reduces system cost by reducing number of information (reduction in number of terminals, cable wires and bay computer digital inputs) to the bay computer from 26 (36) to 6 (7).
High to medium voltage transformer tap changer position defines transformer output voltage. For SCADA operator is important to know which tap is currently in use. That information is usually provided by bay computer. Tap changer has many tap positions and that would take many terminals, cable wires and digital inputs on bay computer, which is not economic. BCD decoder reduces that cost by transforming 26 (BCD 100 / 26) or 36 (BCD 100 / 36) tap changer position into BCD code without additional power supply.More...

 

Circuit breaker / feeder simulators - CBS

Circuit breaker/disconnector simulator for Factory Acceptance Test - CBS 050 Circuit breaker/disconnector/feeder simulator for Factory Acceptance Test - CBS 070 Circit breaker / feeder simulator CBS is speeds up switchgear cabinets Factory Acceptance Test by simulating circuit breaker and disconnector positions.
Switchgear cabinets for medium and high voltage switchgears are ussually wired and tested without switchgear. For testing purpose disconnectors and circuit breakers position is needed. Circit breaker / feeder simulator CBS is intended for simulating circuit breaker and disconnector positions. Simulator CBS come in many variants according to customer requirements. It can simulate one circuit breaker or whole feeder.More...

 

2 port communication media converters - CMU 100 / x.x.x

2 port communication media converter CMU 100 provides a customer many options with designing his communication with equipment on the substation (protection relays, voltage regulators, energy meters,.....). It provides conversion between RS232, RS485, multimode (660 nm & 820 nm) fiber optic, singlemode (1300 nm & 1310 nm) fiber optic, 10/100BASE-TX and 100BASE-FX (ethernet). Converters power supply is designed for standard substation voltages; 24 VDC, 48VDC, 110VDC,125VDC, 220VDC, 230 VAC.
There is a lot of equipment on the substion that need to communicate to the remote data center. Communication media converters are needed to convert data betwee many standardised electrical communication levels (RS232, RS485,..) and medias (wire, plastic & glass optic
fibre).More...

RS232 to RS485 Converter 110-220VDC Ediseja 21 CMU100/1.1.5 RS485 to Multimode Fiber Optic Converter 110-220VDC Ediseja 21 CMU100/1.5.6 RS232 to Multimode Fiber Optic Converter 110-220VDC Ediseja 21 CMU100/1.6.1 RS232 to Ethernet 10/100BASE-TX Converter 110-220VDC Ediseja 21 CMU100/1.1.9 RS485 to Ethernet 10/100BASE-TX Converter 110-220VDC Ediseja 21 CMU100/1.5.9 Multimode Fiber Optic to Ethernet 10/100BASE-TX Converter 110-220VDC Ediseja 21 CMU100/1.6.9 RS232 to Singlemode Fiber Optic Converter 110-220VDC Ediseja 21 CMU100/1.1.S RS485 to Singlemode Fiber Optic Converter 110-220VDC Ediseja 21 CMU100/1.5.S Multimode Fiber Optic to Singlemode Fiber Optic Converter 110-220VDC Ediseja 21 CMU100/1.6.S

 

3-4 port communication media converters & star couplers - CMU 100 / x.x.x.x.x

3-4 port communication media converter / star coupler CMU 100 provides a customer many options with designing his communication with equipment on the substation (protection relays, voltage regulators, energy meters,.....). It provides conversion between RS232, RS485, multimode (660 nm & 820 nm) fiber optic, singlemode (1300 nm & 1310 nm) fiber optic, 10/100BASE-TX and 100BASE-FX (ethernet). Converters power supply is designed for standard substation voltages; 24 VDC, 48VDC, 110VDC,125VDC, 220VDC, 230 VAC.
There is a lot of equipment on the substion that need to communicate to the remote data center. Communication media converters are needed to convert data betwee many standardised electrical communication levels (RS232, RS485,..) and medias (wire, plastic & glass optic
fibre)ports devices from CMU series are power substations communication converters and star couplers. CMU wide range voltage power supply allows connection to all common power substation DC power supply. Additionaly it can be also connected to standard AC voltages.More...

RS232 to 2xRS232 Star Coupler 110-220VDC Ediseja 21 CMU100/2.1.1.1RS232 to 2xMultimode Fiber Optic Star Coupler 110-220VDC Ediseja 21 CMU100/2.1.6.6

 

5-8 port communication media converters & star couplers - CMU 100 / x.x.x.x.x.x.x.x.x

5-8 port communication media converter CMU 100 provides a customer many options with designing his communication with equipment on the substation (protection relays, voltage regulators, energy meters,.....). It provides conversion between RS232, RS485, multimode (660 nm & 820 nm) fiber optic, singlemode (1300 nm & 1310 nm) fiber optic, 10/100BASE-TX and 100BASE-FX (ethernet). Converters power supply is designed for standard substation voltages; 24 VDC, 48VDC, 110VDC,125VDC, 220VDC, 230 VAC.
There is a lot of equipment on the substion that need to communicate to the remote data center. Communication media converters are needed to convert data betwee many standardised electrical communication levels (RS232, RS485,..) and medias (wire, plastic & glass optic
fibre).More...

RS232 to 7xMultimode Fiber Optic Converter Star Coupler 110-220VDC Ediseja 21 CMU100/2.1.6.6.6.6.6.6.6 RS485 to 7xMultimode Fiber Optic Converter Star Coupler 110-220VDC Ediseja 21 CMU100/2.5.6.6.6.6.6.6.6 Ethernet 10/100BASE-TX to 7xMultimode Fiber Optic Converter Star Coupler 110-220VDC Ediseja 21 CMU100/2.9.6.6.6.6.6.6.6 Multimode Fiber Optic to 7xRS232 Converter Star Coupler 110-220VDC Ediseja 21 CMU100/2.1.6.6.6.6.6.6.6 4xMultimode Fiber Optic to 4xRS232 Converter 110-220VDC Ediseja 21 CMU100/2.6.1.6.1.6.1.6.1

 

40 port communication media converters & star couplers - CMU 200

40 port communication media converter CMU 100 provides a customer many options with designing his communication with equipment on the substation (protection relays, voltage regulators, energy meters,.....). It provides conversion between RS232, RS485, multimode (660 nm & 820 nm) fiber optic, singlemode (1300 nm & 1310 nm) fiber optic, 10/100BASE-TX and 100BASE-FX (ethernet). Converters power supply is designed for standard substation voltages; 24 VDC, 48VDC, 110VDC,125VDC, 220VDC, 230 VAC.
There is a lot of equipment on the substion that need to communicate to the remote data center. Communication media converters are needed to convert data betwee many standardised electrical communication levels (RS232, RS485,..) and medias (wire, plastic & glass optic
fibre).More...

CMU

 

16 channel signalization devices (alarm annunciators) - LSU 100 / 16

LSU 100 / 16 is 16 channel local signalization uni (alarm annunciator) in power substations. Device wide range voltage power supply allows connection to all common power substation DC power supply.More...

LSU

 

32 channel signalization devices (alarm annunciators) - LSU 110 / 32

LSU 110 / 32 is 32 channel local signalization uni (alarm annunciator) in power substations. Device wide range voltage power supply allows connection to all common power substation DC power supply.More...

LSU

 

4 channel signal transducers - STR 100

STR 100 series transmits statuses of 4 digital inputs to 4 digital outputs to other STR 100 device and vice versa. Devices are connected via communication link. Fast communication protocol inserts only small delay. More...

STRSTR

 

4 DI 4 DO acquisition unit - SAU 100

SAU 100 is simple acquisition unit with 4 digital inputs, 4 digital outputs, wide range power supply and IEC 60870-5-103 protocol. More...

SAUSAU